Product Overview
YD-9X is used for pre-job alcohol detection and attendance linkage in railways, public security, airports, mines, construction sites, drivers, high-risk industries and heavy industry workshops.The equipment adopts a wall-mounted structure, the alcohol air blowing port is opened with the pressing panel, and can be closed and stored when idle; the project can be equipped with ultraviolet disinfection, which is suitable for testing points that are required for equipment hygiene, space and fixed installation.
Core Strengths
Pre-job testing process
Technical parameters
| Product Name | 10.1 inch face recognition alcohol detection all-in-one machine |
|---|---|
| Product Model | YD-9X |
| Identification method | Face Recognition |
| Recognize Patterns | 1:N |
| Identify Distance | 0.5m–3m |
| User Capacity | 40k Local Face Library |
| Processor | Quad-core 64-bit Cortex-A55, up to 2.0GHz |
| Display | 10.1 "IPS Full View LCD Touch Display |
| Communication method | LAN/Wi-Fi/4G (optional) |
| Development Environment | Android、Linux、Windows |
| Development and Interface | Support OEM, ODM, SDK, API; provide TCP, HTTP, MQTT cloud middleware development materials |
| Installation method | Wall-mounted |
| Operating voltage | 12V / 3A |
| Operating Temperature | -20℃~60℃ |
| Product Dimensions | 287.4 × 278.15 mm |
| Optional features | 4G, temperature detection, ultraviolet disinfection |
The type of alcohol sensor, measuring range, accuracy, calibration cycle, ultraviolet disinfection configuration, and overall protection performance shall be subject to the corresponding batch technical documents and project configuration.
Temperature measurement module parameters (optional)
| Detection Distance | Maximum 1m, recommended optimal distance 0.5m |
|---|---|
| Measurement accuracy | ≤ ±0.3℃ |
| Measurement range | 10℃~42℃ |
| Thermal Image Array | 32 × 32 |
| Exception Reminder | Supports setting of body temperature alarm values, and can be linked to platform early warning |
Alcohol Detection Module Parameters
| Sensor type | 16mm electrochemical fuel cell |
|---|---|
| Measurement range | 0~400mg/100mL |
| Allowable error | Standard operating conditions ± 4.0mg/100mL (± 0.02 mg/L) |
| Sensitivity | 5mg/100mL |
| Show requirements | Error message displayed when standard gas concentration is below 100mg/100mL BAC |
The above temperature measurement and alcohol module parameters are organized according to the current product series data. The actual module configuration, measuring range, accuracy and calibration cycle are subject to the corresponding batch technical documents.
Platform supervision and abnormal warning
Equipment inspection records can be centrally uploaded to the pre-job safety management platform and associated with personnel, work number, equipment and inspection time.When the alcohol result is abnormal or the detection status triggers the rule, a reminder can be sent to the management to help the enterprise form a closed loop of detection, warning and supervision.

Opening and storage structure




Wall-mounted connector

Applicable Industries
- Pre-employment testing of railway systems, airports and transport personnel
- Public security system and safety management of personnel in key places
- Access to mines, construction sites, heavy industry workshops and high-risk industries
- Fixed test points with requirements for wall mounting, alcohol module storage and hygiene management
Frequently Asked Questions
How does the YD-9X's pressed alcohol module work?
When testing is required, press the panel to open the blowing module and close the storage after use to reduce the long-term exposure of the blowing part in the idle state.
Does it come with UV disinfection?
UV disinfection is an optional feature, and the specific configuration needs to be confirmed at the time of project selection and quotation.
What is the difference between YD-9X and YD-9XY?
The YD-9X has a wall-mounted structure, focusing on face and alcohol detection; the YD-9XY has a desktop structure, and increases blood pressure and blood oxygen detection.
Is it possible to connect to an existing platform?
Supports OEM, ODM, SDK and API integration, and can provide TCP, HTTP, MQTT cloud middleware development materials.
Need to confirm the wall mount connector and optional features of the YD-9X?
Please provide the installation location, daily testing number, networking method, ultraviolet disinfection requirements, and existing platform interface.
Submit project requirements